| Pump Casing | SS 202 |
|---|---|
| Motor Housing | SS 202 |
| Impeller | Cast Iron |
| Shaft | SS 410 |
| Seal | Tungsten Carbide vs Tungsten Carbide |
| Max. Liquid Temp. | 50°C |
|---|
| Model | HP | kW | Outlet Size (mm) | Solid Size (mm) | 2 | 4 | 6 | 8 | 10 | 14 | 18 | 24 | 28 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BloRaD I-10DT | 1 | 0.75 | 50 | 12 | Discharge in lpm | 400 | 352 | 304 | 240 | 144 | ||||
| BloRaD I-15DT | 1.5 | 1.1 | 50 | 15 | 800 | 660 | 460 | 160 | ||||||
| BloRaD II-15DT | 1.5 | 1.1 | 50 | 12 | 470 | 430 | 385 | 335 | 270 | 70 | ||||
| BloRaD I-20DT | 2 | 1.5 | 50 | 15 | 900 | 800 | 625 | 440 | ||||||
| BloRaD II-20DT | 2 | 1.5 | 50 | 15 | 550 | 525 | 485 | 437 | 380 | 225 | ||||
| BloRaD I-30DT | 3 | 2.2 | 50 | 12 | 400 | 385 | 370 | 360 | 325 | 275 | 175 | 65 | ||
| BloRaD I-30FT | 3 | 2.2 | 75 | 15 | 880 | 800 | 700 | 600 | 370 | 120 | ||||
| BloRaD I-50DT | 5 | 3.7 | 50 | 12 | 750 | 720 | 690 | 650 | 580 | 480 | 270 | 105 | ||
| BloRaD I-50FT | 5 | 3.7 | 75 | 15 | 1100 | 1070 | 1050 | 1000 | 820 | 590 | ||||
| BloRaD I-75FT | 7.5 | 5.5 | 75 | 15 | 1375 | 1305 | 1250 | 1180 | 1045 | 875 | 500 | 170 | ||
| BloRaD I-100FT | 10 | 7.5 | 75 | 15 | 2400 | 2300 | 2200 | 2100 | 1875 | 1575 | 1000 | 500 |
| Model | HP | kW | Outlet Size (mm) | Solid Size (mm) | 4 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 45 | 50 | 55 | 60 | 65 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BloRaD-50GT | 5 | 3.7 | 100 | 20 | Discharge in lpm | 2200 | 1760 | 920 | 65 | |||||||||||
| BloRaD-75GT | 7.5 | 5.5 | 100 | 20 | 2400 | 2100 | 1400 | |||||||||||||
| BloRaD-100GT | 10 | 7.5 | 100 | 20 | 2400 | 2200 | 2000 | 1750 | 1400 | 1000 | 500 | |||||||||
| BloRaD-125GT | 12.5 | 9.3 | 100 | 20 | 2500 | 2350 | 2150 | 1950 | 1700 | 1400 | 1000 | 550 | ||||||||
| BloRaD-150GT | 15 | 11 | 100 | 20 | 2800 | 2600 | 2400 | 2175 | 1950 | 1700 | 1400 | 1100 | 750 | 350 | ||||||
| BloRaD-200GT | 20 | 15 | 100 | 20 | 2640 | 2550 | 2400 | 2220 | 2040 | 1860 | 1620 | 1380 | 1080 | 660 | 180 | |||||
| BloRaD-100IT | 10 | 7.5 | 150 | 30 | 3900 | 3200 | 2000 | |||||||||||||
| BloRaD-125IT | 12.5 | 9.3 | 150 | 30 | 4500 | 3850 | 2800 | 1250 | ||||||||||||
| BloRaD-150IT | 15 | 11 | 150 | 30 | 4500 | 3950 | 3350 | 2600 | 1800 | 950 | ||||||||||
| BloRaD-200IT | 20 | 15 | 150 | 30 | 5000 | 4500 | 4000 | 3400 | 2750 | 2000 | 1200 | 400 | ||||||||
| BloRaD-250IT | 25 | 18.5 | 150 | 25 | 3800 | 3500 | 3150 | 2800 | 2400 | 2000 | 1600 | 1100 | 450 | |||||||
| BloRaD-300IT | 30 | 22 | 150 | 25 | 4000 | 3800 | 3500 | 3200 | 2800 | 2500 | 2100 | 1700 | 1100 | 500 | ||||||
| BloRaD-350IT | 35 | 26 | 150 | 25 | 4400 | 4200 | 3900 | 3650 | 3300 | 3000 | 2600 | 2200 | 1650 | 1050 | 550 | |||||
| BloRaD-400IT | 40 | 30 | 150 | 35 | 7250 | 6050 | 6080 | 5350 | 4550 | 3190 | 2395 | |||||||||
| BloRaD-500IT | 50 | 37 | 150 | 35 | 8150 | 7875 | 6950 | 6200 | 5650 | 4850 | 4100 | 3387 | 2134 | 1334 | ||||||
| BloRaD II-400IT | 40 | 30 | 150 | 30 | 4350 | 4080 | 3890 | 3710 | 3550 | 3370 | 3120 | 2880 | 2580 | 2300 | 1850 | 1350 | 600 | |||
| BloRaD II-500IT | 50 | 37 | 150 | 30 | 4400 | 4220 | 4100 | 3990 | 3690 | 3505 | 3290 | 3050 | 2350 | 2350 | 1890 | 1400 | 700 |
| Model | HP | kW | Outlet Size (mm) | Solid Size (mm) | Discharge in lpm | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 24 | |||||
| BoIRaD-250IT | 25 | 18.5 | 200 | 35 | 6750 | 6300 | 5925 | 5300 | 4500 | 3750 | 2550 | 1500 | |
| BoIRaD-300IT | 30 | 22 | 200 | 35 | 7125 | 6750 | 6300 | 5700 | 5150 | 4125 | 3000 | 675 | |
| BoIRaD-350IT | 35 | 26 | 200 | 35 | 7650 | 6900 | 6525 | 6525 | 6000 | 5400 | 4725 | 3000 | |
Algo Pumps is a trusted Construction Dewatering Pumps Supplier in Uitenhage, providing dependable pumping solutions for removing accumulated water from construction sites, excavations, foundations, trenches, pits and other temporary dewatering applications.
Our Construction Dewatering Pumps in Uitenhage can be selected according to required flow rate, total dynamic head, water characteristics, solids content, excavation depth, discharge distance and installation conditions. Correct pump selection helps maintain workable site conditions and supports efficient water removal during construction activities.
As a reliable Construction Dewatering Pumps Supplier in Uitenhage, Algo Pumps supports contractors, infrastructure companies, industrial facilities and project teams with application-based dewatering pump selection.
Construction dewatering pumps are used to remove groundwater, rainwater and accumulated water from working areas where dry or controlled site conditions are required. Pump selection should consider both hydraulic requirements and the condition of the water being pumped.
Suitable for removing accumulated water from compatible excavations and earthwork areas.
Pumping solutions for controlling water around foundation pits and suitable construction zones.
Suitable for removing water from trenches during pipeline, utility and civil construction work.
Suitable for water removal from collection pits, sumps and temporary site drainage points.
Can support compatible road, utility, civil and infrastructure dewatering requirements.
Suitable for temporary removal of rainwater and accumulated water from compatible work sites.
Correctly selected pumps help remove accumulated water according to the required flow and head.
Effective dewatering can help maintain more manageable working conditions in compatible construction areas.
Suitable for excavations, trenches, foundations, pits and other temporary construction drainage duties.
Pump selection can be matched to water conditions, solids, flow, head and installation requirements.
Selecting the right construction dewatering pump requires evaluating the amount of water to be removed, required total head and actual site conditions. Water containing sand, silt or suspended solids may require a different pump configuration from relatively clean drainage water.
Pumping distance, excavation depth, pipe diameter, electrical supply and operating duration should also be considered before selecting the appropriate dewatering pump.
Algo Pumps provides pumping solutions for construction, drainage and dewatering requirements. Matching the pump with actual site conditions, required flow, head and water characteristics helps support dependable dewatering performance.
Pump selection based on actual site, hydraulic and water-handling requirements.
Support for evaluating flow, head, solids, discharge distance and installation conditions.
Suitable solutions for excavations, foundations, trenches, pits and compatible infrastructure projects.
Pump selection considers the complete dewatering system instead of relying only on motor power.
Algo Pumps serves customers looking for Construction Dewatering Pumps in Uitenhage for excavations, foundations, trenches, construction pits, civil works and infrastructure projects.
If you are searching for Construction Dewatering Pumps Supplier in Uitenhage, share your required flow rate, total head, site depth, water characteristics, solids content and discharge requirements with Algo Pumps to discuss a suitable dewatering solution.
Share your required flow rate, total head, site depth, water characteristics and discharge requirements with our team to discuss a suitable construction dewatering solution.